Kontakt
QR-Code für die aktuelle URL

Story Box-ID: 728991

BIOTRONIK Woermannkehre 1 12359 Berlin, Deutschland http://www.biotronik.com
Ansprechpartner:in Frau Manuela Schildwächter +49 30 689051414
Logo der Firma BIOTRONIK
BIOTRONIK

BIOTRONIK BIOLUX P-I Clinical Study Published in Journal of Endovascular Therapy

Vascular Intervention

(PresseBox) (BUELACH, Switzerland, )
Results Demonstrate Advantage of BIOTRONIK's Passeo-18 Lux Drug-Coated Balloon Catheter for the Treatment of Superficial Femoral and Popliteal Artery Disease

BIOTRONIK, a leading manufacturer of cardio- and endovascular medical technology, announced today that results of its BIOLUX P-I clinical study have been published in the esteemed Journal of Endovascular Therapy.

BIOLUX P-I was a prospective, international, multi-center, first-in-human, randomized, controlled trial that enrolled 60 patients at five centers in Germany and Austria. The study assessed the safety and efficacy of the Passeo-18 Lux drug-coated balloon (DCB) in treating de novo and restenotic femoropopliteal lesions, and the positive results were instrumental in gaining CE mark in December 2013.

Data collected at six and 12-month intervals demonstrated that patients treated with Passeo-18 Lux DCB were less likely to require treatment again.

At six months, patients treated with the Passeo-18 Lux DCB had a significantly lower late lumen loss (LLL) (0.51±0.72 vs. 1.04±1.00; p=0.033) and binary restenosis rate (11.5 percent vs. 34.6 percent; p=0.048) compared to the control percutaneous transluminal angioplasty (PTA) treated patients. Correspondingly, clinically-driven target lesion revascularization (TLR) was lower in the Passeo-18 Lux DCB group at 12 months (16.0 percent vs. 52.9 percent; p=0.020) for the as-treated population. In addition, patients receiving treatment with Passeo-18 Lux showed greater improvement in Rutherford class compared to baseline (72.0 percent) versus those receiving treatment with PTA (65.2 percent).

"The study has generated the positive clinical data required to prove the validity of Passeo-18 Lux as an efficacious therapy in the treatment of femoropoplieteal vessels," commented Dr. Dierk Scheinert, primary investigator of BIOLUX P-I, University Hospital Leipzig, Germany. "With restenosis following treatment with standard PTA balloons as a significant issue, Passeo-18 Lux is proven to be an effective and durable treatment option in treating disease in the more challenging peripheral vascular anatomy."

The results of the study are being used by BIOTRONIK as a foundation to further investigate Passeo-18 Lux in real world populations, such as the BIOLUX P-III All-Comers Registry, which is currently enrolling patients in Europe and Asia Pacific. Results from BIOLUX P-I are in line with other scientific data, suggesting that treatment with DCB is a viable option and has the potential to become the standard for treating femoropopliteal arteries.

"The publication of the BIOLUX P-I study is another positive milestone in displaying the Passeo-18 Lux DCB as the appropriate therapy option for lower limb arterial disease," commented Dr. Alexander Uhl, BIOTRONIK Vice President Marketing, Vascular Intervention. "Keeping in line with BIOTRONIK's culture of heavy investment in clinical studies, we will continue to investigate and prove its effectiveness so that patients and physicians can choose this product with the fullest confidence."

About Passeo-18 Lux

Passeo-18 Lux is a novel combination device for treating de novo and restenotic lesions in the infrainguinal arteries. Its design is based on that of the proven Passeo-18 uncoated balloon catheter, combined with a balloon coating containing a matrix of anti-proliferative paclitaxel and Butyryl-Tri-Hexyl-Citrate, a biocompatible excipient to enable optimal drug transfer to the target lesion tissue. This coating is also applied to Pantera Lux, a clinically proven coronary drug-coated balloon. Passeo-18 Lux also features the unique 'SafeGuard' insertion aid, which improves ease of handling and protects the user and balloon coating from contact and damage. After use, SafeGuard can simply be peeled away.

Website Promotion

Website Promotion

BIOTRONIK

One of the world's leading manufacturers of cardio- and endovascular medical devices, BIOTRONIK is headquartered in Berlin, Germany, and represented in over 100 countries by its global workforce of more than 5,600 employees. Several million patients have received BIOTRONIK implants designed to save and improve the quality of their lives, or have been treated with BIOTRONIK coronary and peripheral vascular intervention products. Since its development of the first German pacemaker in 1963, BIOTRONIK has engineered many innovations, including BIOTRONIK Home Monitoring®; the world's first 4F-compatible 200 mm peripheral stent; Orsiro, the industry's first hybrid drug-eluting stent; and the world's first implantable cardioverter defibrillators and heart failure therapy devices with ProMRI® technology.

For more information, visit: www.biotronik.com

Für die oben stehenden Stories, das angezeigte Event bzw. das Stellenangebot sowie für das angezeigte Bild- und Tonmaterial ist allein der jeweils angegebene Herausgeber (siehe Firmeninfo bei Klick auf Bild/Titel oder Firmeninfo rechte Spalte) verantwortlich. Dieser ist in der Regel auch Urheber der Texte sowie der angehängten Bild-, Ton- und Informationsmaterialien. Die Nutzung von hier veröffentlichten Informationen zur Eigeninformation und redaktionellen Weiterverarbeitung ist in der Regel kostenfrei. Bitte klären Sie vor einer Weiterverwendung urheberrechtliche Fragen mit dem angegebenen Herausgeber. Bei Veröffentlichung senden Sie bitte ein Belegexemplar an service@pressebox.de.
Wichtiger Hinweis:

Eine systematische Speicherung dieser Daten sowie die Verwendung auch von Teilen dieses Datenbankwerks sind nur mit schriftlicher Genehmigung durch die unn | UNITED NEWS NETWORK GmbH gestattet.

unn | UNITED NEWS NETWORK GmbH 2002–2024, Alle Rechte vorbehalten

Für die oben stehenden Stories, das angezeigte Event bzw. das Stellenangebot sowie für das angezeigte Bild- und Tonmaterial ist allein der jeweils angegebene Herausgeber (siehe Firmeninfo bei Klick auf Bild/Titel oder Firmeninfo rechte Spalte) verantwortlich. Dieser ist in der Regel auch Urheber der Texte sowie der angehängten Bild-, Ton- und Informationsmaterialien. Die Nutzung von hier veröffentlichten Informationen zur Eigeninformation und redaktionellen Weiterverarbeitung ist in der Regel kostenfrei. Bitte klären Sie vor einer Weiterverwendung urheberrechtliche Fragen mit dem angegebenen Herausgeber. Bei Veröffentlichung senden Sie bitte ein Belegexemplar an service@pressebox.de.